MIB Parameters List
Table K-3Private MIB Parameters List
Name
OID
Type
Access
Description
winlink1000OduAdmProductType
1.3.6.1.4.1.4458.1000.1.1.1 DisplayString RO ODU configuration description.
winlink1000OduAdmHwRev
1.3.6.1.4.1.4458.1000.1.1.2 DisplayString RO Hardware Revision of the ODU.
winlink1000OduAdmSwRev
1.3.6.1.4.1.4458.1000.1.1.3 DisplayString RO Software Revision of the ODU.
winlink1000OduAdmLinkName
1.3.6.1.4.1.4458.1000.1.1.4 DisplayString RW
Link Name. A change is effective immediately.
winlink1000OduAdmResetCmd
1.3.6.1.4.1.4458.1000.1.1.5 Integer RW
Reset Command. A set command with a value of
3 will cause a device reset. The read value is
always 0.
winlink1000OduAdmAddres
1.3.6.1.4.1.4458.1000.1.1.6 IpAddress RW
ODU IP Address. A change is effective only after
reset. The above attribute is kept for backwards
compatibility reasons
winlink1000OduAdmMask
1.3.6.1.4.1.4458.1000.1.1.7 IpAddress RW
ODU Subnet Mask. A change is effective only
after reset. The above attribute is kept for
backwards compatibility reasons
winlink1000OduAdmGateway
1.3.6.1.4.1.4458.1000.1.1.8 IpAddress RW
ODU default gateway. A change is effective only
after reset. The above attribute is kept for
backwards compatibility reasons
winlink1000OduAdmBroadcast
1.3.6.1.4.1.4458.1000.1.1.10 Integer RW
This parameter is reserved to the element
manager provided with the product.
winlink1000OduAdmHostsTable
N/A
Table of traps destinations. Each trap destination
is defined by an IP address and a UDP port. Up to
10 addresses can be configured.
winlink1000OduAdmHostsEntry
N/A
Table entry. INDEX {
winlink1000OduAdmHostsIndex }
winlink1000OduAdmHostsIndex
RO Indexing of table.
winlink1000OduAdmHostsIp
1.3.6.1.4.1.4458.1000.1.1.12.1.2 IpAddress RW
Trap destination IP. A change is effective
immediately.
winlink1000OduAdmHostsPort
1.3.6.1.4.1.4458.1000.1.1.12.1.3 Integer RW
UDP port of the trap destination. A change is
effective immediately.
winlink1000OduBuzzerAdminState
1.3.6.1.4.1.4458.1000.1.1.13 Integer RW
This parameter controls the activation of the
buzzer while the unit is in install mode. A change
is effective immediately. The valid values are:
disabled (0)
winlink1000OduProductId
1.3.6.1.4.1.4458.1000.1.1.14 DisplayString RO This parameter is reserved to the element
manager provided with the product.
winlink1000OduReadCommunity
1.3.6.1.4.1.4458.1000.1.1.15 DisplayString RW
Read Community String. This variable always
returns ***** when retrieving its value. It is used by
the element manager to change the Read
Community String. The SNMP agent accepts only
encrypted values.