• A common practice is to configure the remote unit first and
then to configure the local unit only if there was no problem in
remote configuration.
• For some of the configuration parameters additional action
must be taken before the new value is loaded. Please refer to
the operation in the parameters description.
• Some of the MIB parameters values are product dependent. It
is strongly recommend using the Winlink™ 1000
ManagerWinlink™ 1000 Manager Application for changing
these values. Refer to the User Manual for each product
specification. Setting wrong value may cause indeterminate
results.
Community String
To control –
• A link, all SNMP requests should address the local ODU IP.
• The local ODU and IDU, use the
"public-bru1"
community
string.
• The remote ODU and IDU, use the
"public-bru4097"
community string.
Private MIB Structure
The private RADWIN MIB consists of the top level sections
• RADWIN Private – Top level of the MIB.
• Products Section – Contains the Object IDs for all ODU
configurations.
• ODU Section – Contains API sets that define the
configuration, status and performance monitoring of the ODU.
• IDU Section – Contains API set that define the configuration
status and performance monitoring of the IDU.
• General Section – Definition of the generic trap description
parameter.
The following sections describe each of the branches individually.