A common practice is to configure the remote unit first and
then to configure the local unit only if there was no problem in
remote configuration.
For some of the configuration parameters additional action
must be taken before the new value is loaded. Please refer to
the operation in the parameters description.
Some of the MIB parameters values are product dependent. It
is strongly recommend using the Winlink™ 1000
ManagerWinlink™ 1000 Manager Application for changing
these values. Refer to the User Manual for each product
specification. Setting wrong value may cause indeterminate
results.
Community String
To control –
A link, all SNMP requests should address the local ODU IP.
The local ODU and IDU, use the
"public-bru1"
community
string.
The remote ODU and IDU, use the
"public-bru4097"
community string.
Private MIB Structure
The private RADWIN MIB consists of the top level sections
RADWIN Private Top level of the MIB.
Products Section – Contains the Object IDs for all ODU
configurations.
ODU Section – Contains API sets that define the
configuration, status and performance monitoring of the ODU.
IDU Section – Contains API set that define the configuration
status and performance monitoring of the IDU.
General Section Definition of the generic trap description
parameter.
The following sections describe each of the branches individually.