User's Manual

WinLink User and Installation Guide Version 1.770 K-165
Interface API
System Configuration
The system includes SNMP agents on both ODU’s. Each agent can be
accessed only from the local side of the link. The management station
can access the SNMP agent using the Ethernet port over any
SNMP/UDP/IP network. The local SNMP agent contains data on both
the local and remote ODU’s and IDU’s. Both agents communicate with
each other over the air using a proprietary protocol. Each ODU has a
single MAC and IP address.
Control Method
Winlink™ 1000 Manager Application provides all the tools and means
to configure and monitor the WinLink™ 1000 link. TheWinlink™ 1000
Manager includes a wizard that guides the user through the installation
and configuration processes. A user who wishes to control and
configure the device using the MIB should follow the following rules.
The connection for control and configuration is to the local
ODU.
All Parameters should be consistent between both of the
ODU’s. Note that the inconsistency of air parameters can
break the air connection. To fix air parameters inconsistency
the user is required to reconfigure each of the ODU’s.