User's Manual Part 2

Installation and Operation Manual Appendix F Hub Site Synchronization
N/A- for Master or Independent Units
Synchronized – for Hub Site Clients
Not Synchronized – for Hub Site Clients
External Pulses: The status of the pulses running through the HSS
cable. The Master generates such pulses. The severity of each of
these states is indicated by green, yellow or red text color. Possible
states are described in
Table
F-2
.
Table
F-2. External Pulse Status
Status Description Text Color
Not Detected Sync pulses not
detected
Green
Generating Unit is HSM and is
generating RFP pulses
Green
Generating and
Detected
Unit is HSM and
generating RFP pulses
and is also receiving
pulses from another
unit. Incorrect
configuration.
Red
Generating and
Improper Detected
Unit is HSM and
generating RFP pulses
and is also receiving
incorrect pulses from
another unit. Incorrect
configuration.
Red
Detected HSC detecting pulses Green
Improper Detected Incorrect RFP and BW
configuration
Red
Multiple Sources
Detected
More than one HSM
generating pulses.
Incorrect configuration.
Red
Æ
To configure the Operational States of the hub site unit
1. Click the Enabled check box
2. Click the Configure button
WinLink 1000 HSS Link Configuration F-7