User's Manual Part 2

Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual
Tes ti ng
Equipment
Management
Station
Local ODU
Inband Loopback
Activation Command
Remote ODU
E1/T1
Interface
E1
Interface
/T1
Figure
5-11. Local Internal Loopback
5.8 Troubleshooting
Use
Table
5-7
and
Table
5-7
to diagnose any faults in the system.
Table
5-6. Troubleshooting
Symptom Remedy
Verify that AC power is connected to the IDU. No power
Verify that the ODU cable is properly wired and
connected.
Complete the installation procedure from the
management software.
No signal
Verify the ODU alignment. Check that the radio
configuration of both site A and site B units are the
same (channel and SSID).
Weak signal Verify the ODU alignment, reconfigure the link.
Verify the beeper sounds the Best Signal sequence.
The WinLink 1000 LEDs show faults in the system or the link.
Table
5-7. Troubleshooting with WinLink 1000 LEDs
LED Status Remedy
PWR Off Check that AC adapter is connected to the
IDU-E and the AC power outlet.
5-18 Troubleshooting