Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual
Close Closes the active alarm window.
5.5 Remote Power Fail Indication
Remote power fail indication indicates to one side that the other side
has had a power failure. The failed site sends a final trap indication
about the power loss just before powering off.
A Dying-Gasp circuit identifies the power failure at a minimum interval
of 20 milliseconds before the IDU crash, during that interval a message
notifying the power failure is sent to the remote end.
Alarm output number 4 indicates link loss due to power failure at the
remote end.
5.6 Link Compatibility
WinLink 1000 indicates the version compatibility via software traps. As
new hardware is added to existing networks compatibility issues may
arise. An incompatibility issue is indicated to the user via a change of
color of the Link Status box on the Main Menu screen. Trap messages
in the Event Log indicate the problems or limitations and suggest
upgrades when appropriate.
The following Link Status messages are given:
fullCompatibility - different software versions that are fully compatible.
Message indicates that upgrade is available.
restrictedCompatibility - different software versions that operate
correctly. However, new features are not supported
softwareUpgradeRequired - different software versions with limited
operation. The link will operate as Ethernet only; a full service will not
be available. The message is software upgrade required.
versionsIncompatibility - different software versions that are not
compatible. User needs to perform local upgrades.
Table
5-5. Link Compatibility Trap Messages
Link State Link Link Status Site Description Site Link Status
5-14 Link Compatibility