User's Manual Part 1

WinLink 1000 Installation and Operation Manual Chapter 4 Configuration
Æ
To configure the Ethernet Mode:
1. From the Configuration menu, select the site to reconfigure.
The Site Configuration dialog box opens.
2. Click Advanced > Ethernet.
3. In the Ethernet Ports Configuration pane, use the drop-down menu
to select the LAN configuration.
4. Click Apply to save the changes.
Note
It is possible to close the Ethernet service by disconnecting the
Ethernet port. The user should be aware that it i possible to close the
port and not have any access to the device. If this should occur the
workaround is as follows:
s
Connect the system from the remote site
Connect via other Ethernet port (IDU-C)
Power down the equipment and connect immediately after the
power up (the fastest way is to enter install mode).
4.11 Setting the Maximum Information Rate
The maximum Ethernet throughput of the link can be limited. The
default setting is Best Effort, where the highest information rate
available for the link conditions and settings is used. (See
Figure
4-15
)
Æ
To set the Ethernet information rate:
1. From the Configuration menu, select the site to reconfigure.
The Configuration dialog box opens.
2. Click Advanced > Ethernet
3. In the Information Rate pane, use the drop-down menu to select
the maximum Information Rate.
Select Other to define the throughput with 8 Kbps resolution
Select Best Effort for the highest information rate possible for the
link conditions and settings.
4. Click Apply to save the changes.
Not
e
WinLink 1000-ACCESS systems have a maximum rate of 2048 kbps.
Setting the Maximum Information Rate 4-27