User's Manual Part 1
WinLink 1000 Installation and Operation Manual Chapter 4 Configuration
4.9 Configuring the Bridge
Bridge configuration is required in various network topologies, such as
protection (1+1) and ring application. The bridge configuration
parameters are located under the Advanced tab of the Configuration
dialog box (
Figure
4-15
).
Figure
4-15. Advanced Configu ation-Ethernet r
ODU Bridge Mode
This parameter controls the ODU mode with two optional values,
• Hub Mode – in Hub mode the ODU transparently forwards the all
the packets over the wireless link.
• Bridge Mode – In Bridge mode the ODU performs both learning and
aging, the aging time of the ODU is fixed at 300 seconds.
Configuring the Bridge 4-25