User's Manual Part 1
Installation and Operation Manual Quick Start Guide
11. Monitor the link quality for about 15 minutes to verify stability.
12. Connect the management station to one of the two IDUs in the link.
13. Double-click the WinLink 1000 Manager icon to start the
application.
14. Click the Installation button to open the installation wizard and
follow the installation steps.
After selection of the radio channel and the link rate (as determined in
the Link Budget Calculator utility), verify that the link quality bar in the
WinLink 1000 manager is within the green range for TDM service and
within the yellow range for Ethernet service.
Note
Achieve the best possible link quality values. In case of radio link loss,
verify the ODU alignment, or change the radio channel in both sides of
the link. When the radio link resumes, continue the installation
process.
Æ
To install the Outdoor PoE (O-PoE):
15. Route the ODU cable from the ODU location (on the roof) to the
O-PoE location (also on the roof). The maximum combined length
of the ODU to Outdoor PoE cable and the O-PoE to user hub/router
(or any other compatible device) cable is 100m.
16. Mount the O-PoE unit to the mast or wall, using the mounting kit
and mounting instructions.
17. Verify that the O-PoE mounting brackets are connected to ground.
18. Connect the O-PoE chassis to ground.
19. Route the O-PoE AC cable along the mast or wall to a
protected/shielded AC outlet.
Warning
Only UL Listed parts and components will be used for installation. Use
UL Listed devices having an environmental rating equal to or better
than the enclosure rating to close all unfilled openings
WinLink 1000 Installing the WinLink 1000 Units 5