After approximately 20 seconds the ODU beeper starts beeping.
This is normal.
5. Verify normal operation of the IDU by the LED indications on the
panel.
Indicator Color Status
PWR Green ON IDU-C only
IDU Orange
Green
ON for short duration during startup
ON during normal operation
ODU Green ON shows normal operation
AIR I/F Orange
Green
ON for short duration during startup
ON shows normal operation
SERVICE Green ON shows normal operation
OFF when Service is configured for
Ethernet only
6. Make an azimuth sweep with the site B ODU of 180 degrees so that
the site A ODU position is learned by the site B ODU.
7. Turn the site B ODU slowly back towards the site A direction,
listening to the beep sequence until optimal alignment is achieved.
Note
Three beeps and a pause is the best signal
Two beeps and a pause, signal quality increased
One beep and pause is no signal change
Any other signal detects no signal between ODUs.
8. Secure the site B ODU to the mast/wall.
9. At site A, adjust the ODU slowly while listening to the beeper
sequence until the best signal is attained.
10. Secure the site A ODU to the mast/wall.