2.7 Connecting the ODU or O-PoE to the IDU
The ODU-IDU cable conducts all the user traffic between the IDU and
the ODU or O-PoE. The ODU-IDU cable also provides -48 VDC supply
and Ethernet to the ODU. The maximum length for one leg of the ODU-
IDU cable is 100m (328 ft) in accordance with 10/100BaseT standards.
When using an O-PoE the maximum length for two legs of the O-PoE
cable is 100m (328 ft) in accordance with 10/100BaseT standards.
The ODU-IDU cable is supplied pre-assembled with RJ-45 connectors,
at the length specified when ordering. If the ODU-IDU cable was not
ordered, use Cat. 5e shielded cable. Wiring specifications are given in
Appendix A
.
Æ
To connect the ODU or O-PoE to the IDU
1. ODU:Route the cable from the ODU to the IDU.
O-PoE: Route the cable from ODU to O-PoE along the mast or wall
2. Secure the cable along its path.
3. ODU: Connect the ODU-IDU cable to the RJ-45 connector on the
IDU designated ODU or WAN.
O-PoE: Connect the ODU-IDU cable to the RJ-45 connector on the
O-PoE designated PoE.
The figures below illustrate typical IDU panels. You may have
differences in your panels depending on the hardware ordered.
Figure
2-2. Typical IDU-E Rear Panel
Figure
2-3. IDU-2E1-AL Rear Panel
Connecting the ODU or O-PoE to the IDU 2-7