User's Manual Part 1
Installation and Operation Manual Quick Start Guide
Æ
To connect AC power to an IDU-C:
1. Connect the power cable socket to the power connector on the
WinLink 1000 front panel.
2. Connect the power cable plug to the mains outlet.
The unit will be turned on automatically upon connection to the
mains.
Æ
To connect DC power to an IDU-C
A special IEC 60320 adapter for -48 VDC or -24 VDC power connection
is supplied with the unit.
Connecting Power to an O-PoE
AC power is supplied to the O-PoE via a 3m (10 ft) 3-prong AC cable
attached to the unit (pigtail). The AC cable is provided with no
termination.
Æ
To connect AC power to an O-PoE:
Connect the power cable to a protected/shielded AC mains outlet.
The unit will be turned on automatically upon connection to the mains.
To maintain Overvoltage (Installation) Category II, install a suitable
surge suppressor device in the branch circuit to limit expected
transients to Overvoltage Category II values.
The limits are based on IEC60664 and are also located in Table 2H of
UL60950 (for mains ≤ 150V, the transient rating is 1500V
for 150V < mains ≤ 300V, the transient rating is 2500V;
and for 300V < mains ≤ 600V, the transient rating is 4000V).
Warning
5. Connecting the User Equipment
Æ
To connect user equipment to the IDU:
1. Connect the user equipment (such as PBX) to the IDU RJ-45 port
designated Trunk:
On the rear panel of the IDU-E
WinLink 1000 Connecting the User Equipment 7