User's Manual Part 1

Chapter 4 Configuration WinLink 1000 Installation and Operation Manual
Table
4-4. Telnet Commands
Command Explanation
display inventory Displays ODU product name, Name, Location,
hardware and software revisions, uptime, MAC
address, IDU product name, IDU software and
hardware revisions
display management Displays IP, Subnet, Gateway, Traps table
display link Displays State, SSID, Channel BW, RSS, TSL,
Frequency/ACS, DFS, Rate/ARA, Distance
display Ethernet Displays Bridge Mode, Aging time, Port table
(State, Status and action)
display tdm Displays Clock Mode, Master Clock Mode,
Current Clock, Quality[1], TDM table (Line
status, Error Blocks)
display ntp Displays Time, Server and Offset
set ip <ipaddr> <subnetMask>
<gateway>
Set the ODU IP address, subnet mask and
gateway
The user must reset the ODU after the command
completion
set trap <index:1-10> <ipaddr>
<port:0-65535>
Set a specific trap from the traps table (set trap
3 10.0.0.133 162)
set readpw <oldpasswd>
<passwd>
Set the read access password (read community)
set writepw <oldpasswd>
<passwd>
Set the read-write access password (read-write
community)
set trappw <oldpasswd>
<passwd>
Set the trap community string
set buzzer <mode:0=OFF,1 =ON> Toggle the buzzer mode (0 – off, 1 – on)
set tpc<power:Value between
minimal TX power, and maximal TX
power>
Set the ODU transmit power. If a wrong value is
entered, both min and max values shall be
displayed in the error reply
set bridge <mode:0=Bridging
OFF,1= Bridging ON >
Set the ODU bridge mode (0 – off, 1 – on)
4-38 Configuration via Telnet