Chapter 2 Installation and Setup AirMux-200 Installation and Operation Manual
2-8 Installation and Setup
2. Connect user hub/router or any other compatible device to the IDU
rear panel RJ-45 port designated LAN. Refer to Appendix A for the
connector pinout.
Use a straight cable for router connection.
Connecting the Power
Before connecting any cable, the protective earth terminals of the
AC/DC adapter must be connected to the protective ground conductor
of the mains power cord. If you are using an extension cord (power
cable) make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or
outside the instrument) or disconnecting of the protective earth
terminal can make this unit dangerous. Intentional interruption is
prohibited.
Power is supplied to AirMux-200 via an external AC/DC converter,
which receives power from 100–240 VAC source and converts it to -48
VDC.
ä
To connect the power:
1. Connect the 2-pin plug of the AC/DC converter to the 2-pin DC
power connector on the IDU rear panel.
2. Connect the AC/DC converter 3-prong plug to the mains outlet.
The unit turns on automatically upon connection to the mains.
Note
Warning