Chapter 2 Installation and Setup AirMux-200 Installation and Operation Manual
2-4 Installation and Setup
Installing AirMux-200 Management Software
AirMux-200 management application is distributed on CD-ROM as an
executable file. The application operates on a PC under any
Windows 98/2000/NT/XP operating system.
ä
To install the AirMux-200 management program:
1. Insert the CD-ROM into your CD-ROM drive.
2. Run Airmux.exe from the CD-ROM drive.
3. Follow the onscreen instructions of the installation wizard to
complete setup of the AirMux-200 management program in the
desired location.
Connecting the ODU to the IDU
The ODU cable conducts all the user traffic between the IDU and the
ODU. The ODU cable also provides -48 VDC supply to the ODU. The
maximum length for one leg of the ODU cable is 100m (328 ft).
The ODU cable is supplied assembled with RJ-45 connectors, at the
length specified when ordering. Spare RJ-45 connectors are supplied
for use if necessary.
1. Route the cable from the ODU location into the building, leaving
some spare. Secure the cable along its path.
2. Connect the ODU cable to the RJ-45 connector on the IDU rear
panel designated WAN. Figure 2-2 illustrates a typical panel of the
IDU.
Figure 2-2. IDU Rear Panel
Mounting and Aligning the ODU
The ODU is the transmitting and receiving element of the AirMux-200
system. The ODU can be mounted on a mast or a wall. In both
installations, the supplied mounting kit is used to secure the ODU.
Appendix B describes the mast/wall installation instructions.