User Manual
AirMux-200 System 2-1
Chapter 2
Installation and Setup
This chapter describes installation and setup procedures for AirMux-
200 system.
After installing the unit, refer to Chapter 3 for configuration
instructions.
In case a problem is encountered, refer to Chapter 5 for test and
diagnostic instructions.
Internal settings, adjustment, maintenance, and repairs may be
performed only by a skilled technician who is aware of the hazards
involved.
Always observe standard safety precautions during installation,
operation, and maintenance of this product.
2.1 AirMux-200 System
AirMux-200 system comprises the following units:
• Outdoor Unit (ODU): An enclosed aluminum frame with a front
sealed plastic cover, containing an integrated transceiver with an
antenna, RF module, modem and standard interfaces. The ODU
stores all the configuration parameters of the AirMux-200 system.
ODU includes a power connector, which receives -48 VDC, and RJ-
45 for Ethernet (including PoE) traffic from the indoor unit (IDU).
The ODU is attached to a mast using a special mounting kit, which
is supplied with the unit.
• Indoor Unit (IDU): The interface unit between the ODU and the user.
It converts 220 VAC to -48VDC, and sends it on to the ODU. The
IDU does not store any configuration data. Therefore there is no
need for additional configuration of the AirMux-200 system when
replacing an IDU.
Warning