4 Operating AirMux-200
Normal Indications
Upon turning on AirMux-200, the PWR LED in the front panel lights to
indicate that AirMux-200 is on. The table below shows the correct status
of the indicators a few seconds after power-up.
Indicator Status
PWR ON
RTCB Green – Blinking
slowly
RT Green – Blinking
slowly
Air Green – Blinking
slowly
Service Green – Blinking
slowly
Troubleshooting
1. PWR LED is off – Check that AC adapter is connected to the IDU
and the AC power outlet
2. RTCB LED is yellow – Check that the IDU/ODU cable is properly
wired and connected
3. RT LED is red – Check that the IDU/ODU cable is properly wired
and connected
4. Air LED is yellow – Complete the installation procedure from the
management software.
5. Air LED is RED – Check the ODU Antenna alignment. Check that the
radio configuration of both local and remote units are the same
(channel and SSID)
6. Service LED is off – Check the TDM service configuration in the
NMS
7. Service LED is yellow – Check that the system is not in loop-back
mode. Check the remote RTCB ports and cables and remote
external equipment.
8. Service led is red – check the local IDU ports, cables and external
equipment