4 Operating AirMux-200
Normal Indications
Upon turning on AirMux-200, the PWR LED in the front panel lights to
indicate that AirMux-200 is on. The table below shows the correct status
of the indicators a few seconds after power-up.
Indicator Status
PWR ON
RTCB Green – Blinking
slowly
RT Green – Blinking
slowly
Air Green – Blinking
slowly
Service Green – Blinking
slowly
Troubleshooting
1. PWR LED is off Check that AC adapter is connected to the IDU
and the AC power outlet
2. RTCB LED is yellow Check that the IDU/ODU cable is properly
wired and connected
3. RT LED is red Check that the IDU/ODU cable is properly wired
and connected
4. Air LED is yellow Complete the installation procedure from the
management software.
5. Air LED is RED Check the ODU Antenna alignment. Check that the
radio configuration of both local and remote units are the same
(channel and SSID)
6. Service LED is off Check the TDM service configuration in the
NMS
7. Service LED is yellow Check that the system is not in loop-back
mode. Check the remote RTCB ports and cables and remote
external equipment.
8. Service led is red check the local IDU ports, cables and external
equipment