Quick Start Guide AirMux-200 Installation and Operation Manual
2 Installing AirMux-200 Units
§ ODU/IDU Cable (Outdoor class, CAT-5e, 4 twisted pairs)
§ UV-rated cable ties
§ Laptop running Windows 2000 or Windows XP
Before the installation
1. Install the AirMux-200 software on the laptop.
2. Verify that all equipment and tools are available
Performing Outdoor Installation
ä
To install the ODU:
1. Route the ODU cable from the ODU location (on the roof) to the IDU
location (inside the building).
2. Mount the ODU unit to the mast or wall, using the mounting kit.
3. Connect the RJ-45 connectors to both ends of the cable, use the
pinout table below:
IDU RJ-45 Wire Color ODU RJ-45 Function
1 White/Green 1
Twisted
2 Green 2
3 White/Orange 3
Twisted
6 Orange 6
Ethernet
4 Blue 4
Twisted
5 White\Blue 5
7 White/Brown 7
Twisted
8 Brown 8
Power
4. Secure the ODU and ground cables to the mast or brackets using
UV-rated cable ties.
5. Repeat the procedure at the remote site.
ä
To align the ODU:
1. Connect power to the IDU.
Warning