Unregulated
Incountrieswheretheradioisnotregulatedtheequipmentcanbeoperatedinany
regulationconfiguration,bestresultswillbeobtainedusingUniversalregulation
configuration.
SafetyPractices
ApplicablerequirementsofNationalElectricalCode(NEC),NFPA70;andtheNational
ElectricalSafetyCode,ANSI/IEEEC2,mustbeconsideredduringinstallation.
NOTES:
1.APrimaryProtectorisnotrequiredtoprotecttheexposedwiringaslongastheexposed
wiringlengthislimitedtolessthanorequalto140feet,andinstructionsareprovidedto
avoidexposureofwiringtoaccidentalcontactwithlightningandpowerconductorsin
accordancewithNECSections72554(c)and80030.
Inallothercases,anappropriateListe dPrimaryProtectormustbeprovide d.RefertoArticles
800and810oftheNECfordetails.
2.ForprotectionofODUagainstdirectlightningstrike s,appropriaterequirementsofNFPA
780shouldbeconsideredinadditiontoNEC.
3.ForCanada,appropriaterequirementsoftheCEC22.1includingSection60andadditional
requirementsofCAN/CSAB72mustbeconsideredasapplicable.
4.OnlyULListedpartsandcomponentswillbeusedforinstallation.UseULListeddevices
havinganenvironmentalratingequaltoorbetterthantheenclosureratingtocloseall
unfilledopenings.
5.Usemin.10AWGexternalprotectiveearthingconductor.
FOR REGULATORY USES ONLY