Installation Guide

Table Of Contents
TVWhiteSpaceInstallationGuide Release1.0 32
General SafetyPracticesandProvisions
3.1.4General
Installationofoutdoorunitsmustbecontractedtoaprofessionalinstaller
Beforeworkingonequipmentconnectedtopowerlinesortelecommunicationlines,
removejewelryoranyothermetallicobjectthatmaycomeintocontactwithenergized
parts
Useextremecar ewheninstallingantennasnearpowerlines
Useextremecar ewhenworkingatheights
WhenusinganACpowersourceforRADWINdevices,alwaysusetheACpoweradapter
suppliedbyRADWIN
Usetherighttools!
Donotmountanradiounitupsidedownorhorizontally.Doingthismayvoidyouprod
uctwarranty.
3.1.5InternalESDProtectioncircuits
RADWINequipmentisdesignedtomeettheETSI/FCC/Aus/NZ/CSAEMCandSafety
requirements.Tofulfilltheserequirements,thesystem'sTelecomlinesattheradiounit/PoE
areTransformerisolatedandincludeinternalESD(ElectroStaticDischarge)Protection
circuits.
3.1.6Ratings
WheninstallinganACpoweredSU:TomaintainOvervoltage(Installation)
CategoryII,installasuitablesurgesuppressordeviceinthebranchcircuit
tolimitexpectedtransientstoOvervoltageCategoryIIvalues.
ThelimitsarebasedonIEC60664andarealsolocatedinTable2Hof
UL60950(formains<=150V,thetransientratingis1500V;for150V<
mains<=300V,thetransientratingis2500V;andfor300V<mains<=
600V,thetransientratingis4000V).
Table31:RADWINTVWhiteSpaceModelRatings
ModelName
InputVoltage&
Current
EnclosureType Oper.Temp
TVWhiteSpaceBase
Station
41.257VDC,1.6A IP67/Type4 40Cto+60C
TVWhiteSpace
SubscriberUnit
42.557VDC,0.7A IP67/Type4 40Cto+60C
FOR REGULATORY USES ONLY