Installation Guide
Table Of Contents
- Installation Guide
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Installation Steps
- 2.1 Prepare Laptop
- 2.2 Connect Laptop to Radio Unit
- 2.3 Update Connectivity Parameters of Radio Unit
- 2.4 Check items to be installed
- 2.5 Prepare Tools
- 2.6 Mount the HBS
- 2.7 Connect HBS antenna
- 2.8 Install SU Mounting Kit
- 2.9 Mounting the SU
- 2.10 Ground Radio Unit
- 2.11 Mounting the Lightning Protection Units
- 2.12 Waterproofing
- 2.13 Connect Radio (External Connections)
- 2.14 Check Connectivity to Radio
- 2.15 Request (and receive) permitted frequencies
- 2.16 Activate HBS
- 2.17 Align SU Unit
- Chapter 3: Safety Practices and Provisions
- Appendix A: Wiring Specifications
- Appendix B: About Antennas
- Appendix C: Terminology
- Appendix D: Certified Antennas
- RADWIN Worldwide Offices
TVWhiteSpaceInstallationGuide Release1.0 3‐2
General SafetyPracticesandProvisions
3.1.4General
• Installationofoutdoorunitsmustbecontractedtoaprofessionalinstaller
• Beforeworkingonequipmentconnectedtopowerlinesortelecommunicationlines,
removejewelryoranyothermetallicobjectthatmaycomeintocontactwithenergized
parts
• Useextremecar ewheninstallingantennasnearpowerlines
• Useextremecar ewhenworkingatheights
• WhenusinganACpowersourceforRADWINdevices,alwaysusetheACpoweradapter
suppliedbyRADWIN
• Usetherighttools!
• Donotmountanradiounitupsidedownorhorizontally.Doingthismayvoidyouprod‐
uctwarranty.
3.1.5InternalESDProtectioncircuits
RADWINequipmentisdesignedtomeettheETSI/FCC/Aus/NZ/CSAEMCandSafety
requirements.Tofulfilltheserequirements,thesystem'sTelecomlinesattheradiounit/PoE
areTransformer‐isolatedandincludeinternalESD(Electro‐Static‐Discharge)Protection
circuits.
3.1.6Ratings
WheninstallinganACpoweredSU:TomaintainOvervoltage(Installation)
CategoryII,installasuitablesurgesuppressordeviceinthebranchcircuit
tolimitexpectedtransientstoOvervoltageCategoryIIvalues.
ThelimitsarebasedonIEC60664andarealsolocatedinTable2Hof
UL60950(formains<=150V,thetransientratingis1500V;for150V<
mains<=300V,thetransientratingis2500V;andfor300V<mains<=
600V,thetransientratingis4000V).
Table3‐1:RADWINTVWhiteSpaceModelRatings
ModelName
InputVoltage&
Current
EnclosureType Oper.Temp
TVWhiteSpaceBase
Station
41.2‐57VDC,1.6A IP67/Type4 ‐40Cto+60C
TVWhiteSpace
SubscriberUnit
42.5‐57VDC,0.7A IP67/Type4 ‐40Cto+60C
FOR REGULATORY USES ONLY