User manual

Communication with additional displays can be performed via following
ports:
RS 232 (COM1),
RS 232 (COM2),
Tcp.
16.5.2. Communication protocol frame
PUE 7 weighing indicator with following displays:
WD display,
WWG display.
To start cooperation of PUE 7 with displays go to parameter <
Sample>
and define an appropriate communication protocol.
Procedure:
Enter parameters’ group < Devices> according to ch. 16 of this
manual,
Choose
Additional display / Sample” then the editing field
<Sample> with the screen keyboard appears,
Inscribe the required frame pattern using the screen keyboard or
choose the it from the list after pressing
.
Specified patterns for displays:
{141}
- Protocol pattern for WD displays
{142}
- Protocol pattern for WWG display
Confirm the changes by pressing .
Notice:
In default settings parameter <
Sample> has ascribed {141}
(WD display).
46