Instruction Manual

Table Of Contents
- 125 -
GND IN
9
OUT 1
10
OUT 2
11
OUT 3
12
OUT 4
13
OUT 5
14
OUT 6
15
OUT 7
16
OUT 8
17
COMMON
(18) YELLOW GREEN
34.3. WE 4 - 4 inputs / 4 outputs module
WE 4 module comprises 4 optoinsulated inputs and 4 optoinsulated
outputs of reed relays, does not require installing additional modules on the
main board of the terminal. The input / output wires are led out via a gland
on the back wall of the housing (3m length).
34.3.1. Technical specification
Parameters of outputs
Quantity of outputs 4
Type of outputs Reed operation contacts
Wire diameter 0,14 - 0,5mm
2
Maximal load-current contact
capacity
0,2A DC
Maximal forward voltage 50V DC
Parameters of inputs
Quantity of inputs 4
Input type Optoinsulated
Wire diameter 0,14 – 0,5mm
2
Control voltage range 5 -24V DC