Manual

- 65 -
21. TECHNICAL PARAMETERS
21.1. Metrological parameters
Display type LCD
Keyboard type Micro switch (500 000 cycles)
Class (OIML) III
Max. Number of A/D converter divisions 838860 x10
Number of verification divisions 6 000
Max. Increment of signal 19.2 mV
Max. Voltage per 1verificated division
3.2 μV
Min. Voltage per 1verificated division
1.0 μV
Max. Temperature of work
+40°C
Min. Temperature of work
-10°C
Min. Impedance of load cell
80 Ω
Max. Impedance of load cell
1200 Ω
Power voltage on load cell 5V
Load cells connection 4 or 6 cables + screen
Output RS232 Standard
Additional display Option
21.2. Ambient conditions
These scales are intended to operate in extended ambient conditions.
Operation temperature: -10°C / to +40°C
Maximal relative humidity: 85% in 40ºC
Mains voltage tolerance: -10% to +10%