User manual
112 
Completing dosing process causes switching off all outputs of the terminal. 
28.6.2.  Instance 2 – Automatic dosing of 2 ingredients on 2 weighing 
platforms  
Description: 
The dosing process consists of 2 ngredients which will be weighed on 2 
weighing platforms:  
•  Weighing Platform 1: ingredient Flour  
•  Weighing Platform 2: ingredient Water 
The dosing process is carried out automatically, and includes a condition,  
that the dosing sequence is strictly determined – dosing of “Water” ingredient 
can be initiated only on completing the dosing process of ingredient “Flour”.  
The condition is marked with signal flags, which determine formulation making 
process between the weighing platforms, in a way which orders dosing Water 
ingredient as the second one. The whole process is described below in  
tables, separately for each weighing platform. 
Dosing process name:  Instance 2 
Dosing process code:  2222 
Dosing process from a termial level: 
Platform 1 
Icon  Step  Value  Description 
1. [CM] Weight 
condition 
Gross<0.1 kg 
Condition checking, unless the weighing 
platform is loaded with a mass exceeding 
100 g  
2. [Z] Zero 
Zero 
Zeroing the weighing platform no. 1 
3. [TI] Delay 
[5s] Open 
valve Flour  
Pending for opening main valve of the 
container with “Flour” 
4. [DA] Automatic 
batching 
1,2 kg [Flour] 
Automtic dosing of product „Flour” to 
obtain 1 kg mass in bulk dosing mode 
(bulk dosing and fine dosing valves are 
opened – Outputs 1 and 2), and 0,2 kg 
mass is dosed using fine dosing valcve 
only –fine dosing valve is opened on 
Output 1 (for two-step dosing process) 