User manual
108 
[EM] 
Give mass 
Function activating a so called: “mass in hand” 
– ingredient’s mass of a dosing process 
supplied in ready packages with precisely 
determined mass. The given mass is added to 
weighed ingredient’s mass, e.g.: ingredient to 
be weighed = 21,8 kg, weighed amount 1,8 kg 
placed on the scale, and 20 kg inserted 
manually. 
[ET] 
Give number  
of batching 
repetitions 
Function determining quantity of batches of 
weighed ingredient, that is added to a dosing 
process. Mass of a single batch is determined 
in a product selected from the database 
(Products database – field Mass). Product’s 
mass is multiplied by a specific value, and such 
determined mass is added to weighing process. 
The function is applicable for weighing products 
in batches.  
[F] 
Set flags 
Function determining a condition (characteristic 
point) in dosing process. The funtion enables 
conditional carrying out another step in dosing 
process. Setting the characteristic point (signal 
flags) in connection with condition flags enables 
mutual conditioning different processes on 
different weighing platforms. 
[CF] 
Flags condition 
Conditional function determining criteria for 
events, which have to occur in order to carry 
out the following step in dosing process.  
28.5. Creating a new dosing process 
Creating a new dosing process is initiated by specifying its name and code, 
followed by determining processes on each of the weighing platforms. 
Procedure: 
•  Press   key and select option < Databases> from main 
menu  then select <
 Dosing processes>, 
•  In order to create a dosing process, press <  Add> key, and 
confirm creating a new record in dosing process database, 
•  Specify name < > and code < > by pressing corresponding hot 
keys, and inserting a name and a code using an on-screen keyboard,  