User manual
105 
28.2. Dosing process structure 
All activities related to the dosing process can be carried out from  
the level of scale. Each dosing process <
> contains: 
•  Its name <
>, 
•  code <
>, 
•  assigned weighing platforms <
> defined on a terminal. 
Each of the weighing platforms can have its specific dosing process. The 
database of dosing processes has the same searching mechanisms for a 
specific record in a database as other terminal databases. 
A dosing process can be searched in a database by:  
•  the name of a dosing process < > 
•  the code of a dosing process <
> 
Processes carried out on different weighing platforms operated by the same 
terminal, can also be dependant on each other, e.g.: dosing on weighing 
platform 2 can be initiated only on completing dosing on weighing platform 1, 
which is confirmed by a signal from appropriate sensor. 
28.3. Local setting of a working mode  
Local settings for the working mode <  Dosing> are accessible  
on pressing a hot key <
 Local parameters>:  
  Ask for multiplier 
Causes setting a question for dosing 
process multiplier, i.e. the number which is 
used to multiply the values of mass of all 
components. 
  Ask for number of cycles 
Causes setting a question on number of 
dosing process cycles, i.e. number of 
repetitions of the same process.  
Confirm batching 
ingredients manually 
Causes enabling manual confirmation by 
pressing “Enter/Print” key on terminal’s 
keyboard for each weighing process.  
No. of weighings for 
calculating the correction 
Determines the number of recent 
measurements which are analyzed for 
calculating automatic correction in dosing  