Specifications

10 SCOPIA Elite 5100 Series Platform Guide
Electrical Safety
ELECTRICAL
S
AFETY
To reduce the risk of damaging power surges, RADVISION recommends installing
an AC surge arrestor in the AC outlet from which the SCOPIA Elite 5100 Series
platform is powered.
A readily accessible listed branch circuit over current protective device rated
20 A must be incorporated in the building wiring.
Grounding on page 10
ESD Procedures on page 11
GROUNDING This SCOPIA Elite 5100 Series platform must be grounded. Contact the
appropriate electrical inspection authority or an electrician if you are uncertain
that suitable grounding is available.
The SCOPIA Elite 5100 Series platform can become dangerous if you interrupt
any of the protective conductors (grounding) or disconnect any of the protective
earth terminals.
The SCOPIA Elite 5100 Series platform must be installed according to the latest
version of the country national electrical codes. For North America, equipment
must be installed in accordance to the applicable requirements in the US National
Electrical Code and the Canadian Electrical Code.
The power cable of the SCOPIA Elite 5100 Series platform should only be
connected to a power outlet that has a protective earth contact. Do not use an
extension cord that does not have a protective conductor (ground).
Caution For North American installations, select a 3-conductor (18 AWG) power
supply cord that is UL listed and CSA certified. The cord must be terminated in a
molded-on plug cap rated 125V/5A, with a minimum length of 1.5m (6 feet) and
no longer than 4.5m (approximately 14 feet).
Caution This is a class I unit. In Denmark, use this unit with an AC cord suited
to Danish specifications. The cord should include an earthing conductor. Plug the
unit into a wall socket outlet which is connected to the protective earth contact. Do
not use socket outlets which are not connected to a protective earth contact!
Varoitus Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan.