The SCOPIA Elite MCU 5000 Series has designated port 1720 for Q.931. You can configure a
different port to use Q.931 (for example, if port 1720 is busy). Q.931 is a telephony protocol used
for establishing and terminating the connections in H.323 calls.
Procedure
Step 1 Navigate to the MCU Advanced Commands section by doing the following:
a. Select the icon.
b. Select Advanced parameters.
c. Locate the H323 SIG port number in the Name column (see Figure 3-31 on page 39).
Figure 3-31 H.323 Signaling Port Configuration
Step 2 Select the icon in the Review column.
Step 3 Enter the port value in the H323 SIG port number field.
Step 4 Select Apply.
Step 5 Select Close.