Specifications
Maintaining the SCOPIA Elite 5100 Series MCU | 35
RADVISION | Administrator Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Configuring the TCP Port Range for H.245 on the SCOPIA Elite MCU
The SCOPIA Elite MCU 5000 Series has designated TCP ports 1024-1324 for H.245. You can set the
base port, which is the lower end of the port range. H.245 is a Control Protocol used for
multimedia communication that enables transferring information about the device capabilities,
as well as opening/closing the logical channels that carry media streams.
The SCOPIA Elite 5100 Series MCU uses 150 ports for H.245, while the SCOPIA Elite 5200 Series
MCU uses 300 ports (except for the SCOPIA Elite MCU 5215, which has the same capacity as the
SCOPIA Elite 5100 Series MCU).
Procedure
Step 1
Navigate to the MCU Advanced Commands section by doing the following:
a. Select the icon.
b. Select Advanced parameters.
c. Locate the CLI section and select More (see Figure 3-26 on page 34).
Figure 3-27 CLI Section
Step 2
Enter the h245baseport command in the Command field.
Note: To see the current port value, select Execute.
Step 3 Modify the port value in the Value field.
Step 4 Select Execute.
Step 5 Select Close.