Specifications
Maintaining the SCOPIA Elite 5100 Series MCU | 34
RADVISION | Administrator Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Using its full capacity, the SCOPIA Elite 5100 Series MCU uses 180 ports for audio and 540 ports
for video, and the SCOPIA Elite 5200 Series MCU uses 360 ports for audio and 1080 ports for video
(except for the SCOPIA Elite MCU 5215, which has the same capacity as the SCOPIA Elite 5100
Series MCU).
Procedure
Step 1 Navigate to the MCU Advanced Commands section by doing the following:
a. Select the icon.
b. Select Advanced parameters.
c. Locate the CLI section and select More (see Figure 3-26 on page 34).
Figure 3-26 CLI Section
Step 2 Set the video base port by doing the following:
a. Enter the advcmdmpcsetval command in the Command field.
b. Enter the mf.BasePort parameter in the Parameter field.
c. Enter the port value in the Value field.
d. Select Execute.
e. Clear the value in the Parameter field before proceeding to the next step.
Step 3 Set the audio base port by doing the following:
a. Enter the setmprtpbaseport command in the Command field.
b. Modify the port value in the Value field.
c. Select Execute.
Step 4 Select Close.