Specifications
Maintaining the SCOPIA Elite 5100 Series MCU | 31
RADVISION | Administrator Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Restoring a Previous Software Version
Perform this procedure to downgrade to the previous MCU software version.
We highly recommend that you contact
RADVISION Customer Support prior to restoring a previous
software version.
Before You Begin
• If you need to restore version 7.5 or 7.6: On the Status tab, verify that the MCU is connected
to the network by checking the Ethernet icon.
Figure 3-24 Status Map Section of the Status Tab
• Verify that there are no active conferences hosted on the MCU by selecting Manage
Conferences and checking that no conferences appear in the Conference
List.
Procedure
Step 1
(Recommended) Save the current MCU custom configuration by performing these steps:
a. In the MCU web user interface, select the maintenance icon .
b. Select Backup configuration and save the generated .zip file.
Step 2 To restore MCU version 7.5 or 7.6, perform the following steps:
a. In the MCU Administrator interface, select the maintenance icon .
b. Select Rollback software.
Note: Restoring the previous version may take up to 15 minutes.
Step 3 After reset, the previous release is installed on the MCU.
The downgrade process returns the MCU configuration back to the previous version—with the
values used prior to the last upgrade.