User guide
36 SCOPIA 400/1000 Gateway User Guide
Initial Gateway Configuration
Procedure
1 Connect the supplied terminal cable to the PC terminal.
2 Connect the power cable.
3 Start the terminal emulation application on the PC.
4 Set the communication settings in the terminal emulation
application on the PC as follows:
Baud rate: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
5 Turn on the power to the Gateway.
6 After the terminal emulator session starts, press the RST
button on the Gateway front panel to reset the module.
A log of the auto-boot events and a VxWorks banner scrolls
across the computer monitor.
Note When the Gateway is started for the first time, two VxWorks banners
appear. The configuration option appears after the second banner.
7 When the message “Press any key to start configuration”
appears on the screen, press any key within 6 seconds.
The network configuration Main menu displays:
Press any Key To start configuration...
Main menu
Enter <N> to configure default network port values
Enter <P> to change the configuration software password
Enter <A> to display advanced configuration menu
Enter <Q> to quit configuration menu and start GW
Caution If you do not press a key before the countdown ends, the device
continues its initialization and you can only configure the device by pressing
the RST button on the front panel.