132 SCOPIA 400/1000 Gateway User Guide
Configuring Port Settings
6 In the Signaling protocol field, select a signaling protocol for use in
call setup from the following list:
RS-366—Carries signaling information only.
Data Triggered—Enables the Gateway to connect a call when it
detects valid incoming data from an endpoint on the serial network.
Manual Control—Enables an Administrator to manually connect a
call via the Gateway web user interface.
Different signaling protocols are available depending on the interface
and terminal adapter that you select, as shown in Table 3-19.
The Signaling protocol field is enabled only you select DTE in the
Interface field. The Signaling protocol field is set to RS-366 and
disabled when you select DCE in the Interface field.
7 In the Incoming default bandwidth field, set the rate to which the
Gateway forces the bandwidth of an incoming call. Available only when
DCE is selected in the Interface field.
8 (Optional) Click Connect Call/Disconnect Call to connect or
disconnect the specified call. Available only when Manual Control is
selected in the Signaling protocol field.
9 Click Reset.
Related Topics
Configuring Signal State and Loopback Control Options
Viewing Connection Status
Table 3-19 DTE/DCE Interface Configuration Options
Interface
Selected
Terminal Adapter Options Signaling Protocol Options
DTE Common RS-366, Manual Control, Data Triggered
KG-Device RS-366, Manual Control, Data Triggered
DCE Common RS-366