Operation Manual
7
MAIN CHARACTERISTICS
Flush Mounting version, standard fixing with 60mm axes.
Large graphic display with backlight
Easy use interface (5 keys with scroll menu).
Several languages available
Graphic view for program with icons to help the creation.
Available for Heating & cooling installations (with reversible heat
pump)
Residual humidity supervision
Possibility to regulate on:
- Air sensor only
- Floor sensor only
- Air & Floor combined with different possibilities.
Temporary override function (2H)
Silent (Triac output)
Sensors Auto checks (Short circuit and breaks)
Permanent memory storage
TECHNICAL CHARACTERISTICS
Measured temperature
precision
0.1°C
Operating temperature
0°C - 50°C
Setting temperature range
5°C - 35°C by 0.5°C step
Regulation
characteristics
- Hysteresis (ON/OFF)
- Proportional Integral (PWM)
Electrical Protection
Class II - IP30
Power Supply
Product consumption:
Full load (without actuators)
standby
Done by the MASTER UFH
230V +/- 10% 50Hz
~ 3,5W
~ 1.8W
Outputs:
Actuator
Pilot Zone A&B
TRIAC
230VAC 75W Max (4 actuators)
2 TRIACS 230VAC.
With a Maximum of 6 thermostats
per zones.
Software version
Displayed during the init (after
power supplying)
Version 1.x x