Symptoms Possible cause(s) Solution
Serial port(s) do not work. Port is disabled in the
Setup screen.
Interrupt conflicts.
Port hardware failure.
Press CTRL+ALT+ESC to enter the
Setup screen. Use cursor arrows to
move to the appropriate field and
toggle the entry to enable the port.
Another module may be using the
same interrupts as COM1 and/or
COM2. Verify that no other card in
system is using IRQ3 or IRQ4.
Replace the EPC.
Common Error Messages
This section contains a summary of error and warning messages alphabetized by
message text. These are messages generated by the BIOS and MS-DOS that may be
related to your hardware configuration.
BAD OR MISSING COMMAND INTERPRETER DOS
Problem: The DOS operating system cannot find the Command line interpreter.
Solution(s): Either COMMAND.COM is not present at the specified (or default)
directory level of the boot disk or the "SHELL=" statement in your
CONFIG.SYS lists the file incorrectly (wrong directory or
misspelled).
CMOS CHECKSUM INVALID BIOS
Problem: Something in the CMOS RAM is incorrect.
Solution(s): Run the BIOS setup program to determine what is wrong, and correct
it. If the error occurs repeatedly, the EPC's battery has failed.