Specifications

Installation
EPC-100 Hardware Reference 2-2
Inserting the EPC-100
!
WHEN HANDLING OR INSERTING THE EPC-100 MODULE, AVOID
TOUCHING THE CIRCUIT BOARD AND CONNECTOR PINS
, AND MAKE
SURE THE ENVIRONMENT IS STATIC
-FREE.
To install the EPC-100 in the cPCI chassis, make sure that the extractor handles on
the front panel are pulled away from each other to their maximum extent. Engage the
chassis guides with the EPC-100 and push it in until the extractor handles rest on the
latch rail extrusion of the cPCI chassis. Complete the insertion by pressing the
extractor handles inwards towards the center of the front panel until the EPC-100 is
fully seated in the chassis and the extractor handles lock into place.
Removing the EPC-100
To remove the EPC-100 from the cPCI chassis, press the latch part of the extractors
inward until the extractor handle swings out and pivots freely. Then pull outward on
the extractor handles until the EPC-100 disengages from the rear connector. Slide
the EPC-100 out of the cPCI chassis and place it in the anti-static bag that it came in.
Configuring the EPC-100
Connecting Peripherals to the EPC-100
!
DO NOT PLUG IN ANY CABLE OR CONNECTOR INTO THE FRONT
PANEL CONNECTORS WHILE THE SYSTEM IS POWERED UP
.
ELECTRONICS EQUIPMENT IS GENERALLY NOT DESIGNED TO
WITHSTAND FLUCTUATIONS IN POWER
. THUS DAMAGE COULD
ARISE FROM PLUGGING IN A DEVICE OR BOARD WHILE POWER IS
ON
. NEVER PLUG IN A SERIAL OR PARALLEL DEVICE, KEYBOARD,
TRANSCEIVER, MONITOR OR OTHER COMPONENT WHILE THE
SYSTEM IS
ON.