Characteristic Value
Temperature operating 100MHz: 0-60°C at point of entry of forced air
derated 2°C per 1000 ft (300 m) over 6600 ft
(2000m)
133MHz: 0-60°C at point of entry of forced air
derated 2°C per 1000 ft (300 m) over 6600 ft
(2000m)
166MHz: 0-45°C at point of entry of forced air
derated 2°C per 1000 ft (300 m) over 6600 ft
(2000m)
200MHz: 0-40°C at point of entry of forced air
derated 2°C per 1000 ft (300 m) over 6600 ft
(2000m)
2°C per hour max excursion gradient
storage -40°C - 85°C
5°C per hour max excursion gradient
Humidity operating 5% - 95% noncondensing
storage 5% - 95% noncondensing
Altitude operating 0 - 10,000 ft (3000 m)
storage 0 - 40,000 ft (12,000 m)
Airflow operating 300 LFPM, (Linear Feet Per Minute)
----continued----