Specifications

EE
LCD Flat Panel Interface
Page 2
Sharp LM64P89 Monochrome LCD
LM64P89 Signal Name EPC-30 Signal Name
1 S 15 FLM (HSYNC)
2 CP1 19 LP (VSYNC)
3 CP2 25 SCLK
4 DISP 9 Vee ENABLE
5 VDD 1 PVCC
6 GND 8 GND
7 -18V (extern) N/C
8 DU0 16 LD4
9 DU1 18 LD5
10 DU2 22 LD6
11 DU3 24 LD7
12 DL0 4 LD0
13 DL1 6 LD1
14 DL2 10 LD2
15 DL3 12 LD3
Table E-1. EPC-30/Sharp LM64P89 Flat Panel Interface.
Refer to Chapter 4, Connectors, for information about the LCD/Flat Panel
connector.
Refer to documentation from the flat panel manufacturer for additional
configuration information.
JP3 Jumper Settings for the LM64P89:
Aoff
Bon
Con
About LCD Flat Panels
LCD flat panel displays fall into two general categories, based upon the
method the manufacturer uses to drive the display pixels. The two categories
are active matrix displays and passive matrix displays. Each display category
suits itself to particular applications and has unique advantages and
disadvantages. Application data for each display category is available from
flat panel manufacturers.