Specifications

Page 93
99
9. Troubleshooting & Error
Messages
Troubleshooting
This section deals with problems that you may encounter that do not provide an error
message. If an error message is displayed, see the next section of this chapter,
Common Error Messages. Always attempt to solve the problem yourself. If you are
unable to solve the problem, call RadiSys Technical Support. Make sure you have
detailed system configuration available before starting your phone call.
Symptoms Possible cause(s) Solution
System appears to boot
(evidenced by RUN LED
being on, floppy and hard
disk being accessed) but
provides no video.
Video adapter not fully
seated in subplane.
Monitor or cable problem.
Video adapter failure.
Subplane failure.
EPC-5A cannot talk to
EXM expansion interface.
Remove the video adapter. If the
subplane is secured to the VMEbus
backplane by retaining screws,
check for over tightening of the
screws. Reinsert the video adapter
and verify seating into the subplane.
Verify that the cable pins are not
bent and the cable is fully seated in
the video adapter. Try the monitor
on another system to verify that the
monitor is good.
Call RadiSys Technical Support.
Call RadiSys Technical Support.
Call RadiSys Technical Support.