Specifications

EPC-5A Hardware & Software Reference Manual
Page 102
99
Boot Failures
The System BIOS attempts to display an error message on the display and halts when
it encounters the following error conditions:
1. Fixed disk error
Causes :
No drive connected
Configured for 0 cylinders
Controller reset failed
Drive not ready
Track 0 seek timed out
Drive initialization failed
Drive recalibration failed
Last track seek failed
2. Timer error
Causes :
System timer (0) failed
3. I/O chip error
Causes :
I/O conflicts exist for serial and parallel ports, hard disk (any or all)
4. Other error
Causes :
IRQ conflicts
The System BIOS prints an error message but does not halt when it encounters
the following error conditions:
1. RTC error
Causes :
RTC lost power
2. CMOS error
Causes :
RTC battery failed
CMOS checksum failed
3. Configuration error
Causes :
Previous POST execution was incomplete