Specifications
EPC-5A Hardware & Software Reference Manual
Page 100
99
NOT READY READING DRIVE ...
Problem: This is usually caused by not fully inserting a diskette into the floppy
drive.
Solution(s): Eject the floppy diskette and reinsert making sure that the diskette
seats completely into the floppy drive.
PARITY ERROR IN SEGMENT ...
Problem: This could be a software error (reading a nonexistent memory area) or
a true hardware failure.
Solution(s): Attempt to repeat the error. If the error occurs during the execution of
your own proprietary software, verify that the memory location
specified in your software is valid.
PRESS A KEY TO REBOOT
Problem: A C: drive partition exists but is not set active.
Solution(s): Run your operating system disk partitioning program (like FDISK)
and set the primary partition active.
REAL TIME CLOCK ERROR - RUN SETUP
Problem: The battery-backed TOD clock is incorrect.
Solution(s): Run the BIOS setup program to determine what is wrong, and correct
it. If the error occurs repeatedly, the EPC-5A’s battery has failed.
TESTING VME (VXI) INTERFACE FAILED
Problem: The BIOS Post has detected that the VME or VXI registers are
invalid.
Solution(s): Attempt to repeat the error. Check all hardware and cable connections.
If the problem persists, there is a hardware error. Contact RadiSys
Technical Support.