Specifications
EPC-8 Hardware Reference
J
J
J-4
Symptoms Possible cause(s) Solution
System will not talk
across VMEbus.
The VMEbus backplane
may not be jumpered
correctly.
More than 1 master may
be set to provide Slot-1
functions.
There may be no Slot-1
controller providing bus
arbitration.
EPC-8 or subplane may
have bent pins.
VMEbus interface failure.
See the section Installing the
VMEbus Backplane Jumpers in
Chapter 2.
Make sure that only 1 system is
configured as the Slot-1 controller
and that it is the left-most system
in the chassis.
Determine if the system is in the
left-most position and that the
Slot-1 controller jumper is set.
Remove the EPC-8 and the
subplane and verify that no pins
are bent. Then reinsert the
subplane and the EPC-8.
Call RadiSys Technical Support.
Table J-1. Troubleshooting Error Messages.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com