Specifications
EPC-8 Hardware Reference
H
H
H-10
Incorrect PROM ID Byte
This message displays when there is a hardware problem in the EEPROM. I/O mode
is thus disabled. Contact RadiSys Technical Support.
(xfer to memory)
(xfer from memory)
Failed after X bytes with X
These messages display if there is a problem during the Buffer Memory test. The first
two messages highlight errors in the transfer of data. The third message identifies
where the data transfer error occurred. This is a fatal hardware error. Contact RadiSys
Technical Support.
Cable Disconnected
Cable Unterminated
These messages indicate faults in the cabling or connection. Check to see if the
network cable is in proper working order, properly connected and terminated. If the
connections are proper and the termination is acceptable, the cables are faulty. If the
cable tests good in another system, the connection is faulty.
No Interrupt
This message displays during the Interrupt Assignment test if the interrupt selected is
not active. Return to the setup function and select another interrupt listed as available.
Boot ROM Failed
This message displays during the Boot ROM Check if the boot ROM does not pass
the checksum test. The user must replace the boot ROM.
Using AUTOSET on Large Systems
If you are using AUTOSET on a system with more than eight (8) EXM slots, you
must use a switch when starting AUTOSET to tell it how many slots are present. For
example, on a system with 20 EXM slots, enter the following:
AUTOSET /20