Specifications

EPC-8 Hardware Reference
H
H
H-8
Diagnostics
Once the LAN adapter is installed and cabled, use the AUTOSET diagnostic program
to check the adapter installation.
Note that the AUTOSET diagnostic program test requires that the adapter be attached
to a properly-terminated network or to a BNC "T" connector that has two terminators
connected (if thin Ethernet is used). Once the cable is installed, use the AUTOSET
diagnostic program to check the network interconnection.
Select the Diagnostics option in the AUTOSET menu. The Initialization and
Diagnostics menu displays. The configuration options currently chosen are listed in
parentheses. The following displays while several options are checked:
Network Interface Controller (12-byte node address)................ OK
Buffer Memory Check ............................................................... OK
Check Cable Connection (Cable Connected)............................. OK
Interrupt Assignment (5)............................................................ OK
Boot PROM Check (No Boot PROM) ...................................... OK
Press ESC to return to the previous menu. If Diagnostics reveals an error, return to the
Display/Change configuration menu and make the necessary changes. Run
Diagnostics again.
Error Messages
The AUTOSET software has several associated error messages that may display
during operation. These error messages are explained below.
Out of memory error
This message displays only during development and should never display during
normal operation. If this message displays, contact RadiSys Technical Support.
No adapter at this address
This message displays when the address selected does not have an Ethernet controller
network adapter card attached. Check the hardware to make sure the Ethernet
controller is properly seated and functioning. If the message continues to display,
select another address such as 300h, 280h, etc. If an address change does not fix the
problem, the Ethernet controller should be replaced.