Specifications

EPC-3305 Hardware Reference
4
Specifications
1
These are system-level tests. The EPC-3305s conformance to these specifications
may be affected by the rest of the systems ability to conform.
Table 1-1. EPC-3305 environmental specifications
Characteristic State Value
Temperature Operating 0°C to 60°C at point of entry of forced air
derated 2°C per 1000 ft (300 m) over 6600 ft
(2000m) with sufficient airflow to keep within
the termperature specification.
Storage 40°C to 85°C
Humidity Operating/storage 5% to 95% noncondensing 10% per hour
maximum excursion gradient
Airflow Operating 200 LFM (linear feet per minute)
Vibration Operating
0.04G
2
/Hz from 51000 Hz random,
10 min. per sweep cycle
Storage
0.06G
2
/Hz from 51000 Hz random,
10 min. per sweep cycle
Shock Operating 30 G, 11 ms duration, half-sine shock pulse
Storage 50G, 11ms, half-sine shock pulse
EMC Operating Designed to pass CE Mark and FCC Class B
ESD
susceptibility
1
Operating 4KV direct contact, 8KV air
Radiated
susceptibility
1
Operating IEC 801-3:1984/EN50082-1 (1992): 3V/m (not
tested)
Performance criteria: A