Specifications

EPC-7 Hardware Reference
22
EPC-7 is not the slot-0 controllerEPC-7 is slot-0 controller
Jumpers
EPC-7 Rear View
Figure 1. EPC-7 Configuration Jumpers.
There are several readily apparent consequences of incorrectly configuring the
EPC-7 configuration jumpers.
Resource manager reports a system configuration differing widely from the
actual configuration
Power-on selftest reports a VXI failure.
CLK10+ and CLK10- signals are not being driven or are out of spec on the
backplane.
The system resource manager could not detect the presence of a non-slot-0
EPC-7.
Power-on selftest reports NO SYSCLK.
System hangs, typically while running the resource manager.
If any of these conditions occur, check the configuration jumpers on the back of the
EPC-7.