Specifications
B
IPMI Commands and Managed Sensors
37
8 +3.3V Voltage Threshold 3.30 Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.06V
Default Thresholds
LNR LC LNC UNC UC UNR
0.00 3.12 3.18 3.47 3.50 3.60
9 +1.8V Voltage Threshold 1.80 Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.02V
Default Thresholds
LNR LC LNC UNC UC UNR
0.00 1.70 1.72 1.89 1.90 2.00
10 +1.2V Voltage Threshold 1.20 Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.02V
Default Thresholds
LNR LC LNC UNC UC UNR
0.00 1.12 1.14 1.32 1.33 1.37
11 MMC Reset OEM Sensor
Specific
Discrete
N/A N/A Reading Bit Flags
0x01 - Hard reset
0x02 - Cold reset
0x04 - Warm reset
0x08 - External reset
0x10 - JTAG reset
0x20 - Power fail reset
0x40 - Software reset
0x80 - MMC watchdog reset
0x100 - First boot
Table 15. Managed sensors (continued)
Number Name Type
Reading
Type
Normal
Reading
Alarm level Notes