Specifications
B
IPMI Commands and Managed Sensors
36
Supported sensors
Table15liststhesensorsmanagedbytheMMC.
Table 15. Managed sensors
Number Name Type
Reading
Type
Normal
Reading
Alarm level Notes
0 Hot Swap Module Hot
Swap
Sensor
Specific
Discrete
N/A N/A Contains module hot swap information as defined in the
AMC.0 Specification
1 +3.3V MP Voltage Threshold 3.30 Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.06V
Default Thresholds
LNR LC LNC UNC UC UNR
0.00 3.10 3.16 3.46 3.51 3.60
2 +12V Voltage Threshold 12.00 Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.16V
Default Thresholds
LNR LC LNC UNC UC UNR
0.06 10.90 11.44 12.61 13.24 13.78
3 Outlet Temp Temp Threshold 25 Minor,
Major,
Critical
This sensor measures temperature in °C
Hysteresis: 2.94°C
Default Thresholds
LNR LC LNC UNC UC UNR
0.05 1.03 2.01 65.71 72.57 80.41
4 Inlet/HDD
Temp
Temp Threshold 25 Minor,
Major,
Critical
This sensor measures temperature in °C
Hysteresis: 2°C
Default Thresholds
LNR LC LNC UNC UC UNR
0 5 10 45 55 65
5 Version
Change
Version
Change
Sensor
Specific
Discrete
N/A N/A Reports version changes as defined in the IPMI v2.0
specification
6 SAS1064E
Temp
Temp Threshold 25 Minor,
Major,
Critical
This sensor measures temperature in °C
Hysteresis: 2°C
Default Thresholds
LNR LC LNC UNC UC UNR
-10 -5 0 80 90 100
7 +5V Voltage Threshold 5.00 Minor,
Major,
Critical
This sensor measures voltage in Volts
Hysteresis: 0.06V
Default Thresholds
LNR LC LNC UNC UC UNR
0.00 4.75 4.79 5.24 5.27 5.52