Specifications

6
Board-level updates for the ATCA-45xx CPM and RTM
64
ThefollowinglistdefinestheOpenSessioncommandoptions:
14istheIPMIchannelnumber
4istherequestedprivilegelevel
2istherequestedauthenticationtype
rootisthedefaultusername
cmmrootpassisthedefaultuserpassword
Update the RTM alarm CPLD
TheproceduresforupdatingtheCPLDfortheRTMaresimilartotheproceduresinUpdatethe
legacyFPGAonpage 58.SeethatsectionforthetwoRPMfilesthatneedtobeinstalled
basedonyourOS.ThefollowingsvffileforupdatingthealarmCPLDisintheATCA5400RTM
<version>/firmware/cpldfolderonthePromentumsoftwarerelease:
cpm7_alarm_commux_bypass_legacy_bypass.svf
ThefollowingareexamplestepstoprogramthealarmCPLDfromarunningRH5system.
ModifythefilenamesaccordingtoyourOS.Thesestepsmustbeperformedwithroot
permissions.
1. Installorupdatetherequiredsoftwarepackages.
rpm‐UvhispVMEmbedded1.25.x86_64.rpmcpm_ioport_module1.05
1.2.6.18_164.el5.x86_64.rpm
2. Starttheioportservice.Thisstepcanbeskippedifyouhaverebootedoralreadystarted
theioportservicesinceinstallationoftheabovesoftwarepackages.
/etc/init.d/cpm_ioport_modulestart
3. ConverttheCPLDsvffiletovme.NotethattheISPtoolsrequirelowercaseextensions.
rsyssvf2vme‐infile<file>.svf‐outfile<file>.vme
4. ProgramthealarmCPLD.
rsysispVME<file>.vme
5. VerifytheRTMalarmCPLDversion:
ddif=/dev/portbs=1count=1skip=15802>/dev/null|xxd
Theversionoutputmaybesimilartothefollowing,whichshowsthealarmCPLDversionis
8:
0000000:81