Specifications

6
Board-level updates for the ATCA-45xx CPM and RTM
60
Update the legacy SPI flash (update only if the legacy FPGA is corrupted)
Note:UpdatethelegacySPIflashonlyifthelegacyFPGAflashiscorruptedduringanupdate.
ToupdatethelegacySPIflash,firstseeUpdatethelegacyFPGAonpage 58forthetwo
requiredpackagesbasedonyourOS.
ThecurrentlegacySPIflashsvffile(*.svf)isalsoneeded.Therearetwosvffilesinthe
firmwareupdatelegacyFpgafolder:oneforusewiththeRTMinstalled,andoneforuse
withouttheRTM.
IftheRTMisinstalled,usethisSPIflashfilethathastheComMuxandalarmCPLDbypassed:
cpm7_legacy_spi_flash_commux_bypass_alarm_bypass_1_6.svf
IftheRTMisnotinstalled,usethisfilethatonlyhastheComMuxbypassed:
cpm7_legacy_spi_flash_commux_bypass_1_6.svf
ThefollowingareexamplestepstoprogramthelegacySPIflashfromarunningRH564bit
system.ModifythefilenamesinthecommandsaccordingtoyourOS.
Note:Thesestepsmustbeperformedwithrootpermissions.
1. Installorupdatetherequiredsoftwarepackagesiftheywerenotalreadyinstalled during
UpdatethelegacyFPGAonpage 58.
rpm‐UvhispVMEmbedded1.25.x86_64.rpmcpm_ioport_module1.05
1.2.6.18_164.el5.x86_64.rpm
2. Starttheioportservice.Thisstepcanbeskippedifyouhaverebootedoralreadystarted
theioportservicesinceinstallationoftheabovesoftwarepackages.
/etc/init.d/cpm_ioport_modulestart
3. Convertthesvffiletovme.NotethattheISPtoolsrequirelowercaseextensions.
rsyssvf2vme‐infile<file>.svf‐outfile<file>.vme
4. ProgramthelegacySPIflash.
rsysispVME<file>.vme
Updating the RTM MMC firmware, FRU, and alarm CPLD
TheseproceduresdescribehowtoupdatethefirmwareandsoftwarefortheATCA540xRTM
andATCA4580RTM.
DetermineIPMBandIPMBLaddressestocompletetheRTMfirmwareandFRUupdates.See
AppendixB,IPMBandIPMBLaddressmapping,onpage 85forinformationaboutRTMand
AMCIPMBLaddresses.Forfurtherdetails,refertothespecificshelforcarrier
documentation.